Main Functions
(1) Suitable for energy storage use. High efficiency, long life and high reliability;
(2) High precision voltage sample (30mV/cell) and current sample (1A@<100A);
(3) Advanced algorithm of SOC\SOH. System calculates the real time SOC value of battery pack
automatically.
(4) Protection functions:
◇ Over and under voltage protection of entire pack and single cell;
◇ Charge and discharge over current protection;
◇ Charge and discharge over or under temperature protection;
◇ Short circuit protection;
◇ Charge reverse polarity protection;
(5) Intelligent cell equalization management. Automatically balance each cell through passive balancing
method;
(6) Communication functions: including RS232/RS485, etc.;
(7) With monitoring software running on host computer to configure the BMS:
◇ Set the protection voltage \current value and warning voltage\current value and etc. ;
◇ Read the current SOC value,cell voltage and current working status and etc. ;
(8) Automatically switch on\off: when the system is suspended it will turn off automatically. When there
is charge voltage or load on the pack, the system will wake up automatically.
(9) Support multi packs working in parallel.
(10) 5U19 inch standard cabinet。
(11) Fan-based thermal control: When the temperature sensor detects over high temperature inside the
battery module, the fan inside the module will operate automatically to reduce the temperature inside the module;
- Parameter
Item | Parameters | Remark |
Model | SRLI-48100AH | / |
Rated Voltage(V) | 48 | / |
Typical Capacity(Ah) | 100 | 25℃ 1C discharge |
Standard Charge Voltage(V) | 58.4 | Can be set |
Maximum Charge Current(A) | 10 | / |
Continuous Discharge Current(A) | 10 | / |
Maximum Discharge Current(A) | 50 | / |
Over-charge protection voltage (V) | 58.4 | Can be set |
Over-discharge protection voltage (V) | 40 | Can be set |
Over-charge protection voltage of single cell(V) | 3.65 | Can be set |
Over-discharge protection voltage of single cell (V) | 2.5 | Can be set |
Over-discharge protection current (A) | 50 | Can be set |
Maximum Temperature Protect at Charge( ℃) | 10 | Can be set |
Minimum Temperature Protect at Charge ( ℃) | 50 | Can be set |
Maximum Temperature Protect at Discharge ( ℃) | 70 | Can be set |
Minimum Temperature Protect at Discharge ( ℃) | -20 | Can be set |
BMS leakage current(mA) | ≤1 | |
Maximum Balanced Current(mA) | 200 | |
Dimensions(mm) | 482(width)*222 (height)*450(length) | |
Weight(kg) | 56 | Net weight |